- Junction of the casing elements should be done in following way:
- Using a fastening unit.
- Using universal clamp. Universal clamp is used for lengthening of casing elements. Due to bearing on profile it is possible to refuse using battening bars.
- Use hammer not bigger then 800 g for mounting of fastening unit and universal
clamp. Mounting should be performed by slight hits of hammer on wedges until gap
between two attached frames disappear.
Attention! It is strongly prohibited to use sledgehammer for mounting of
clamps! Use usual hammer only.
- Mounting points of fastening unit and universal clamp are shown on pic. 13. Due to round crimp on the profile, it is possible to join elements anywhere. Due to this, stepless moving of the casing elements by height is possible.
- Necessary number of universal clamps, set depending on height and positioning of casing elements are shown in Table 1.
| Vertical positioning of the element |
Horizontal positioning of elements |
| Element height |
Number of clamps |
Element width |
Number of clamps |
| 1,35m |
2 |
0,30m |
1 |
| 2,85m |
2 |
0,45m |
1 |
| 3,30m |
3 |
0,60m |
2 |
| |
|
0,90m |
2 |
| |
|
1,35m |
2 |
|