  1. Using the adjusting timber and universal clamps from 0 to 15 cm.



It is possible to make compensation with step of 1 cm by compensation of adjusting timbers 2, 3, 5 and 10 cm.


It is not necessary to set clamping bar for compensation up to 5 cm.
  1. Compensation of horizontally set casing elements.
  2. Using the adjusting timber and universal connector from 0 to 15 cm.

  3. Using adjusting timber and adjustable fastening unit from 0 to 20 cm.
  4. Adjustable fastening unit is mounted on the same places as universal clamp.
  5. Using compensating plate from 4 to 30 cm.
  6. All holes which are free from anchors should be closed by corks from the concreting side.

  7. Using profile bar and casing plate from 0 to 80 cm
  8. Compensation range:
    Clamping bar 0,90 m – from 0 to 30 cm
    Clamping bar 1,50 m – from 0 to 80 cm




    Set one anchor through jack in upper and lower clamping bars if compensation width is less then 30 cm. If the compensation width is bigger then 30 cm, two anchors should be set through all three clamping bars.