ABOUT US     NEWS     CERTIFICATES     ARTICLES     MANUFACTURE     CONTACTS  
EN  |  RU
To check up a mail
Company News
Big5 2009, UAE, Dubai

10. Rules of building-up casing elements



We will be glad to see you on exhibition ANGA Cable 2009, which will take place 26 - 28 May in Cologne Fair Grounds, Hall 10.2, stand K48, Cologne, Germany
  1. With frame elements 3,30 m long and fastening units.
  2. Note. All sizes in centimeters.
    Casing height 3,60 m 3,75 m

    Х) It is necessary to set anchors on the upper edge of casing if you using scaffolds for concreting
    Casing height 3,90 m *)

    *) Clamping bar is not needed if anchors set on the upper casing edge.
    Casing height 4,20 m 4,65 m
  3. If the casing height less then 3,75 m, 2 fastening units should be mounted on each element junction (maximum element width not exceeding 1,35 m).
  4. If the casing height is up to 5,40 m, 1 clamping bar and 2 fastening units should be mounted on each element junction (maximum element width not exceeding 1,35 m).

    Exclusion:
    Clamping bar should not be mounted on the upper, horizontally set element, up to 0,60 m high.
    Only one clamping bar should be mounted on the upper, horizontally set element, higher then 0,60 m high.

  5. Casing height
    4,95 m **) 5,10 m 5,25 m 5,55 m

    **) Clamping bar should not be mounted on the upper, horizontally set element, up to 0,60 m high.
  6. If the casing height is up to 8,10 m, 1 clamping bar and 2 quick-acting clamps should be mounted on each element junction (maximum element width not exceeding 1,35 m).

    Exclusion:
    Only one clamping bar should be mounted on the upper, horizontally set element, up to 0,90 m high.